Immediately stops current screen movement.
bottom
101 Moving to 2642
x
203 Screen stopped at 1034
12V-Trigger control
To operate the Supernova Flex through contact closures, a pluggable terminal block
connection is available.
The terminal block has seven positions for wires.
For contact closure operation, the five terminals on the left side of the terminal block are used.
The operation of the screen through this port is as follows:
Label Name Description
C
Common Common wire, shorted to others for control.
Momentarily connect to common to raise the screen
incrementally. The screen will rise as long as this contact
remains shorted to common.
Raise
Momentarily connect to common to lower the screen
incrementally. The screen will lower as long as this contact
remains shorted to common.
Lower
Momentarily connect to common to send the screen to the
preprogrammed top position. It is not necessary to continue
connecting to common after motion begins.
Top
Momentarily connect to common to send the screen to the
preprogrammed bottom position. It is not necessary to
continue connecting to common after motion begins.
Bottom
For 12-Volt trigger operation, the two terminals on the right side of the terminal block are used.
Applying 5V to 12V (AC or DC) to these two terminals will cause the screen to lower to the
bottom position; removal of the voltage will cause the screen to return to the top position.
Polarity is not important (either polarity works for DC voltage).